Core-Fill 500 Foam Insulation
Codes & Standards
Home
Product Overview
Applications
Codes & Standards
Specifications
Brochure
Company Profile
Contact Us
Classified by Underwriters Laborit

Tailored Chemicals Products, Inc.
Technical Presentation
TEST
REFERENCE
REQUIREMENTS
CORE-FILL 500™

Thermal Resistivity
D.O.E. (e)(2)H.U.D. 6.2.7
R-Value not less than 4.0 per inch
R - 4.91
per inch
Fire Safety
ASTM E-84
Flame spread not to exceed 25
Flame spread* 0
Smoke density 5
Corrosiveness
D.O.E. (e)(3)H.U.D. 6.2.8
Al, Cu, Steel - no Perforations; Galvanized steel - no pitting; Loss in mass not to exceed 0.2g
No perforations
No pitting
Less than 0.1g
Density
D.O.E. (e)(4)H.U.D. 6.1.4
Dry 0.7 to 0.9 lb/ft3
Wet 2.5 to 5.5 lb/ft3
0.8 lb/ft3
2.7 to 3.3 lb/ft3
Water Absorption
D.O.E. (e)(5)H.U.D. 6.2.9
Not to exceed 15%
No absorption in less than 1 hour
Floating test 3%Droplet test - 1 hr.15 min.
Acoustic Properties
ASTM E-90
STC Rating 50
STC Rating 53
OITC Rating 44
Shrinkage
D.O.E. (E)(11)H.U.D. 6.2.5
Not more than 4.0%
Less than 1%

*This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions


Thermal Properties
INSULATION VALUE
CONSTRUCTION
"U"
VALUE
"R"
VALUE
Foam in CMU Cores
(Parallel Heat Flow)
8" CMU / 60lb. density
8" CMU / 100lb. density
12" CMU / 60lb. density
12" CMU / 100lb. density
.07
.10
.05
.08
14.2
9.1
20.0
12.5
12" Utility Brick Wall System
4" Nominal Outer Wall
4" Cavity Space filled
with Core-Fill 500
4" Nominal Inner Wythe
.04
23.2

R-Values vary with block density. Certain R-Values taken from National Concrete Masonry Association publications.

Series parallel valuations provided upon request.

 


Home | Product Overview | Applications | Codes & Standards
Specifications | Brochure | Company Profile | Contact Us

© 2013 Tailored Chemical Products, Inc. All rights reserved